Products
Home Products Battery Pack Equipment Li ion Battery Tester

20V10A 8 Channel Lithium Battery Testing Equipment Battery Capacity Tester

Product Categories

Contact Us

  • Contact Person : Louis Yang
  • Email : Louis@lithmachine.com
  • Address : No. 5 Nanshan Road, Huli District, Xiamen City, Fujian Province, China
20V10A 8 Channel Lithium Battery Testing Equipment Battery Capacity Tester

20V10A 8 Channel Lithium Battery Testing Equipment Battery Capacity Tester

  • ItemNo :

    LITH-BTS-20V10A
  • MOQ :

    1
  • Place of Origin:

    China
  • Color :

    optional
  • Port :

    Xiamen Port
  • Compliance:

    CE
  • Warranty:

    2 years
  • Delivery Time:

    5 days
  • Email :

    Louis@lithmachine.com
  • Product Details
20V10A 8 Channel Lithium Battery Testing Equipment Battery Capacity Tester

INTRODUCTION:

Battery tester is mainly used to detect current, voltage, capacity, internal resistance, temperature, battery cycle life, and gives the graph. Battery tester has many channels to choose from. It can start at a single point, control at a single point, and measure different types of batteries (nickel-hydrogen, nickel-cadmium, lithium-ion, etc.).

 

Specific test functions include: battery voltage, load voltage (voltage difference), internal resistance, short-circuit protection time, short-circuit protection recovery function, over-discharge current, charging function, identification resistance (R1, R2), code reading, capacity test (including charge and discharge test).


SPECIFICATION:

Project index                                             Parameter index
Input Power AC 220V ±10% / 50Hz
resolution AD16bitDA16bit
Input Resistance ≥1MΩ
Input Power 2228W
Channel Features Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control Mode Independent Control
Voltage Constant voltage
control range
0.1V~20V
Minimum discharge
voltage
2.5V
Accuracy ± 0.1% of   FS
Stability ± 0.1% of   FS
Current Per Channel Current
Range
0.05A~10A
Accuracy ± 0.1% of   FS
Stability ± 0.1% of   FS
Constant voltage
cut-off current
0.02A
Stability ± 0.1% of   FS
Power Single channel maximum output
power
200W
Stability ± 0.2% of   FS
Time Current Response
Time
Maximum current rise time 20ms
Step Time Range ≤365*24 h
Time Form Support 000000(hmins、ms)
Data Recording Record Condition Timet100ms
VoltageU40mV
Minimum current interval: 20mA
Record Frequency 10Hz
Charge Charge Mode Constant Current ChargeConstant Voltage Charge
CC-CV Charge  CP-Charge
End Condition VoltageCurrentRelative TimeCapacity-V
Discharge Discharge Mode Constant Current Discharge   CP-D CR-D
End Condition CurrentCurrentRelative TimeCapacity-V
Pulse Model Charge Constant CurrentConstant Power
Project index                                             Parameter index
Discharge Constant CurrentConstant Power
Min Pulse Width 500ms
Pulse Number Single Pulse Step Support 32 different Pulse
Charge r To Discharge One Pulse Step Can Support Continuous Charge And Discharge Change
Stop Condition Voltage Relative Time
DCIR Testing Support Custom Access Point And Count The DCR
Cycle Loop Measure Range 1~65535 times
Max Steps Per Loop 254
Nested Loop Nested loop FunctionMax Support 3 Layers
Protection Software Protection    Power-down Data Protection
   Setting Protection ConditionSetting ParameterLow Voltage limitUpper Voltage limitLow Current limitUpper Current limitDelay Time
IP protection level IP20
Voltage and Current Testing Sample 4-wire connecting
Noise <85dB
Data Management MySQL Database
Communication Means TCP/IP Protocol
Data Output EXCELTXT
Communication Interface Ethernet Port
Main Channels 8
Data output mode EXCEL 2003,2010TXT
Communication interface Mesh port
Server disk configuration 500GB
Leakage current <5uA


Equipment Working Environment

Project index                                             Parameter index
Working Temperature Range 0~40℃(within the range of 25 ± 10 ℃, ensure the measurement accuracy: the accuracy drift is 0.005% of FS / ℃)
Storage Temperature Range -10~50
Working Environment Relative Humidity
Range
≤ 70% RH (no water vapor condensation)
Storage Environment Relative Humidity
Range
≤ 80% RH (no water vapor condensation)
Battery Clamps    
Project index                                             Parameter index
Equipment Picture
Picture for Reference Only, take the material object as the standard.




                          

                                      

                                                                  








PACKAGE:

  1 Standard exported package: Internal anticollision protection, external export wooden box packaging.

  2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.

  3 Responsible for the damage during the shipping process, will change the damaged part for you for free.

 

DELIVERY TIME:15-20 days after confirming the order, detail delivery date should be decided according to 

production season and order quantity.