ItemNo :
LITH-VTL1700MOQ :
1Port :
XiamenCompliance:
CEWarranty:
1 yearDelivery Time:
5 daysEmail :
Louis@lithmachine.comLab 1700C High Vacuum Diffusion Pump Vertical Tube Quenching Furnace
Detailed parameter information
Model |
VTL1700-I |
VTL1700-II |
VTL1700-III |
Power |
7.5KW |
7.5KW |
7.5KW |
Tube size |
Dia60(OD)X1000mm |
Dia80(OD)X1000mm |
Dia100(OD)X1000mm |
Dimension(LXDXH) |
1300X500X800mm |
1300X500X800mm |
1300X500X800mm |
Supply voltage |
220V/380V |
||
Phase |
single phase |
||
Heating element |
· 1800 MoSi2 heating element |
||
Tube |
Corundum tube: high purity AIO ceramics (containing) 99.5% |
||
Control mode |
Use Yudian program temperature control instrument (standard) 1. 50-segment program temperature control intelligent PID adjustment. 2. With over-temperature protection. The electric furnace heating circuit is automatically cut off when over-temperature protection or over-temperature protection occurs. (When the temperature of the electric furnace exceeds 1720 degrees or the thermocouple is blown, the AC relay on the main circuit will be automatically disconnected, the main circuit is disconnected, the ON light on the panel is off, the OFF light is on, and the electric furnace is limitedly protected). 3. With 485 communication interface (standard configuration when purchasing software). 4. It has a power failure protection function, that is, when the furnace is powered on after the power is turned off, the program does not start from the initial temperature, but starts from the furnace temperature when the power is turned off. 5. The meter has the function of temperature self-tuning.
(replacement of imported instruments requires additional payment and purchase)
FP93 control instrument(SHIMADEN) EUROTHERM touch screen |
||
Break couple protection and display |
Yes |
||
Over-temperature protection |
Yes |
||
Overcurrent protection |
Yes |
||
Control precision |
+/- 1 ℃ |
||
Flip-flop |
Phase-shifted trigger |
||
Electric appliance |
Zhejiang chint |
||
Silicon controlled |
· 106/16E SEMIKRON |
||
Max. temp |
1700 ℃ |
||
Rated temp |
1650 ℃ |
||
Heating rate |
≤20 ℃/ Min (can be modified as required) |
||
Recommended heating rate |
≤5℃/ Min |
||
· Thermocouple Type |
B |
||
Heating length |
300mm |
||
Electrical certification |
CE |
||
Ambient surface temperature |
≤45℃ |
||
Vacuum seal flange and valve |
1. A stainless steel sealing flange and stainless steel needle valve are installed on the top of the furnace body. 2. A bottom plate valve, a non-mechanical pressure gauge, and a KF25 vacuum interface are used to connect the vacuum pump at the bottom of the furnace body. 3. Vacuum degree: The vacuum degree of the mechanical pump can be less than 1Pa. If you want to obtain a higher vacuum degree, you can choose a domestic or imported high vacuum unit. The vacuum degree can reach 10-3Pa. Optional: The following accessories increase vacuum efficiency. 4. KF25 stainless steel bellows, KF25 quick remover clamp. 5. Optional anti-corrosion digital vacuum gauge with a measurement range of 3.8x10-5 to 1125 Torr. No coefficient conversion is required due to different types of measurement gases.
6. At the top of the flange is installed an electromagnet sample hanging device that can withstand a maximum of 500g. As shown in Figure 1, the sample is hung on the hook through the hanging wire, as shown in Figure 2. Click the control button of the sample hanging device of the electromagnet. The hanging wires fall together into the quenching box, as shown in Figure 3. Before releasing the sample, 5 PSI of argon must be flushed in and the manual flapper valve at the bottom of the furnace tube opened. Pic 4 is the hanging wire
Pic 1 Pic 2 Pic 3 Pic 4 |
||
Quenching container |
1. A stainless steel box for holding the quenching liquid is fixed at the bottom of the furnace tube. 2. A large manual plug valve is installed between the bottom of the furnace tube and the liquid box. |
||
Guarantee period |
One year warranty, lifetime technical support Special Note: 1. Consumable parts such as heating elements, furnace tubes, sample crucibles, etc. are not under warranty. 2. Damage caused by the use of corrosive gases and acid gases is not covered by the warranty. |
PACKAGE:
1 Standard exported package: Internal anticollision protection, external export wooden box packaging.
2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.
3 Responsible for the damage during the shipping process, will change the damaged part for you for free.
DELIVERY TIME:15-20 days after confirming the order, detail delivery date should be decided according to
production season and order quantity.