Products
Home Products Vacuum Glove Box

Customized Single-Side Vacuum Glove Box With H2O & O2 Purification System

Product Categories

Contact Us

  • Contact Person : Louis Yang
  • Email : Louis@lithmachine.com
  • Address : No. 5 Nanshan Road, Huli District, Xiamen City, Fujian Province, China
Customized Single-Side Vacuum Glove Box With H2O & O2 Purification System

Customized Single-Side Vacuum Glove Box With H2O & O2 Purification System

  • Product Details

Customized Single-Side Vacuum Glove Box With H2O & O2 Purification System 


Structure 

         Integrated structure (Purification System integrated under the box)

Power Supply

        110 - 220V AC, 50/60Hz, Single-phase

Glove box Box

      Box Material: 304 Stainless Steel (Type 304), thickness 3mm 
Box Size(excluded antechamber and  support): 1500mm(L) x 750mm(W) x 900mm(H) 
59.1" x 29.5" x 35.4"
Box Support height: 900mm(35.43" )

Tray  

        Standard Layout

        Customized Single-Side Vacuum Glove Box With H2O & O2 Purification System

            Two layers in box.

 

       Option/Add: tool boxes or other
       Customized Single-Side Vacuum Glove Box With H2O & O2 Purification System

 

      Various tool boxes, can be placed according to user needs.

Front window

      Tilt design operating window, removable safety toughened glass front window, 8mm thickness,Wear resistance, corrosion resistance, good light transmission, sealing ring using 3/8 inch thick OMEGA sealing ring.

      Option: Window  Open

      The front window can be designed to open instead of fix, in order to put in a variety of instruments (custom function).Customized Single-Side Vacuum Glove Box With H2O & O2 Purification System

Environment of Box inside

       H2O <1 ppm (20°C/68 ℉, 1 atm) 
  O2 <1 ppm (20°C/68 ℉, 1 atm)

Antechamber 

      Control way: manual 
Design: two circular antechambers 
Main chamber size: Φ360mm (Dia.)x 600mm(length)(location: right-side of box) 
14.17 "(Dia.) x 23.62" (L) 
Mini chamber size: Φ150 mm(Dia.) x 300mm(L)(location: right-side of box) 
5.9 "(Dia.) x11.8" (L) 
Vacuum degree:<=-0.1MPa(right side antechambers included main chamber and mini chamber, all of that are need vacuum and display. The vacuum pressure gauge brand is German WIKA.

Option/add auto control way

 

      It will automatically control the antechamber by time setting and the number of times for gas exhaust and filling.

    Option/Add:  heating mode 

       Max temperature:200℃/ 392℉ 
Control accuracy:±2℃/±3.6℉ 
The main chamber and mini chamber are both can adding the heating function (compared with standard antechamber the size is a little different)

Working gas and regeneration gas

      Working gas: 99.999% high pure N2, Ar, He and other inert gas 
Control gas:99.999% high pure inert gas 
Regeneration gas: mixing gas of working gas and H2,hydrogen(H2)Volume accounted for 5-10% 
If the pure system only has moisture removal function, the regeneration gas is the same with working gas

Gas purification system

     Single pure column: 
German BASF Oxygen removal material, US UOP high moisture absorb material. The regeneration process of purification system is auto control and automatic moisture and oxygen removal function. 
Gas purity can be sustained and keep long-term:H2O<1ppm, O2<1ppm.

 Option: dual columns purification system 
(one in use and the other is reserve)

      Why choose duel pure column? 1,The Pure column need to be regenerated after saturated by absorbing the oxygen and moisture. The regeneration time is 16hours. If there is no reserved column, it may stop working. (we recommend dual column purification system to factory or other unit which need glove box working Continuously); 2,The pure capacity of dual pure columns is two times as much as single column

Pressure control system

     Box pressure can be auto controlled by PLC touch screen 
Control accuracy:±1Pa 
Can also be manually controlled by foot switch

Filter system

      The ends of inlet and outlet both are provided with filter 
The filter precision is: 0.3 mu m

Closed circulating fan

      High speed frequency conversion fan, flow 0-100m3/h, microprocessor control, Stainless steel device for pressure testing. 
With water cooling device (can equipped with water cooler and external refrigeration equipment)

Control system 

    SIEMENS colors touch screen (6 inches), PLC control system, Bilingual in Chinese and English can be switched 
Pressure sensor: -2500~2500Pa touch screen, accuracy±1Pa 
Pressure control: control the box pressure to one setting point (scope can be set)

measurements 

    Moisture analyzer: US GE brand, 0~1000ppm touch screen display, precision 0.1ppm

    Oxygen analyzer: US GE brand, 0~1000ppm touch screen display, precision 0.1ppm

Vacuum Pump 

     Britain Brand EDWARDS, pumping speed 8.4-12m3/h, Model: RV12 
Extreme pressure 2 x 10-3 mbar/1.5 x 10-3 Torr 
Inlet flange NW25
Outlet flange NW25
Noise level: 50 Hz h, 48 dBA

Glove 

     Brand: US NORTH 
Material: Butyl 
Model for standard:8B1532

illumination system

      Equipped with Fluorescent lamp. Brand: PHILIPS

Solvent removal system

      Efficient adsorption of activated carbon, can effectively remove trace organic solvents;

Spare KF40 standard joint

      Special design to KF40 Joint, you can lead the water into the box 
Customized Single-Side Vacuum Glove Box With H2O & O2 Purification System

Can be connected to  other devices          (low temperature refrigerator, film coating machine, microscope, solvent purification system, low temperature cold trap, heating furnace, etc.)

      low temperature refrigerator

       Customized Single-Side Vacuum Glove Box With H2O & O2 Purification System

microscope

        Customized Single-Side Vacuum Glove Box With H2O & O2 Purification System

     Solvent Purification System

         Customized Single-Side Vacuum Glove Box With H2O & O2 Purification System

    Coating machine

Inside connection(one door of Coating machine is inside of glove box) 
 Customized Single-Side Vacuum Glove Box With H2O & O2 Purification System
Outside connection 
Customized Single-Side Vacuum Glove Box With H2O & O2 Purification System

Equipment size and room requirements

Overall size

      2150mm(L) x 1000mm(W) x 1950mm(H) 
." x39.37" x 76.77"

Room size

      2200mm(L) x 1500mm(W) x 2000mm(H) 
86.6" x59" x 78.74"

Wooden Package size and weight

      2485mm(L) x 1145mm(W) x 2300mm(H) 
97.83" x 45" x 91" (6.5M3)

      700 kg (1510 lbs)

Notice

     When the gas is circulating, must ensure that the piping of the circulation system is clear and cannot be blocked (if the color of the filter is changed from white to black, the filter should be replaced timely). 
No corrosive gas in the glove box. 
It needs to regenerate the column when the moisture and oxygen indicators cannot meet the work requirements.            If the corrosive gas is released from inside of glove box.(such as LiPF6 electrolyte),please do not use. you must put the bottle filled with liquid seal. 
Vacuum pump needs to be checked the oil level and maintain in regular time.



Process

Power Processing→Power Grinding→Vacuum Mixing→Electrode Coating→Roll Press→Sheet Cutting→Vacuum Drying→Ultrasonic Welding→Electrode Winding→Spot Welding→Grooving→Glove Box→Electrolyte Injection→Electrode Diffusion→Hydraulic Sealing→Battery Analyzer




Related Machine

 

 Semi Automatic Battery Winding Machine for Cylindrical Battery or Pouch Cell Electrode Making

Semi Automatic Battery Winding Machine for Cylindrical Battery or Pouch Cell Electrode Making 

Semi Automatic Battery Winding Machine for Cylindrical Battery or Pouch Cell Electrode Making 

Semi Automatic Battery Winding Machine for Cylindrical Battery or Pouch Cell Electrode Making 

Electrode Slitting

 

Welding Power:

80-6500W optional

Lab cylindrical cell grooving machine 

 Manual Sealing or Pneumatic Sealing Machine

8 Channel Battery Tester

 

Slitting Machine

Ultrasonic Spot Welding Machine

Grooving Machine

Sealing Machine

Battery Tester







PACKAGE:

  1 Standard exported package: Internal anticollision protection, external export wooden box packaging.

  2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.

  3 Responsible for the damage during the shipping process, will change the damaged part for you for free.

 

DELIVERY TIME:15-20 days after confirming the order, detail delivery date should be decided according to 

production season and order quantity.