Features
1. Lithium Battery Capacity Analyzer mainly constitute by the computer system and control software, communication interface and battery detecting cabinet. Battery detecting cabinet comprises a fixture and placed the plate body of the fixture, charging, constant current and constant voltage source discharge constant current source, storage control circuit, current sampling circuit, voltage sampling circuit, the main control CPU, data memory, microcontroller programming and control panel.
2. Each battery test station has independent constant current and constant voltage power.
3. Using a unique constant current constant voltage power, constant current to constant voltage switch without impact, especially suitable for lithium ion battery charging and discharging requirements.
4. Per device consists of a set of completely independent MCU control system.
5. Specially used for chemical and capacity separation of cylindrical lopo battery.
Customizable current range: 0-1 mA, 0-10 mA, 0-300 mA, 0-2 A, 0-3 A, 0-5 A, 0-20 A, 0-30 A, etc.
Customizable voltage range: 0-5 V, 0-10 V, 0-20 V, 0-30 V, 0-50 V, 0-60 V, 0-150 V, 0-300 V, 0-500 V, etc. LITH-BT0502-256-C is a high pricision 5V2A 256 Channel18650 Cylindrical Battery Capacity Tester used for lithium battery analyzer.
Specifications
Model |
LITH-BT0502-256-C |
Voltage supply |
AC 220V ±5% 50HZ |
Max Power Dissipation |
4500w |
Channel |
256 |
Dimension |
800*500*1900mm |
Support battery height range |
10-95mm( stepless adjustment) |
Clamp spacing |
35mm |
Voltage measurement range |
DC100-4500mV |
Voltage accuracy |
±0.1%FS ±0.1%RD |
Voltage measurement range |
DC100-4500mV |
Voltage resolution |
1mV |
Constant voltage range |
DC2000~4500mV |
Minimum discharge voltage |
2000mV |
Charge discharge current range |
DC5~2000mA |
Current accuracy |
±0.1%FS ±0.1%RD |
Current resolution |
1mV |
Time measurement range |
999min/step |
Time measurement error |
±0.1% |
Working temperature |
0~40 ℃ |
Relative humidity |
≤85% |