ItemNo :
LITH-3H-2000PS2MOQ :
1Delivery Time:
5 daysEmail :
Louis@lithmachine.com
Test Reports:
Adsorption and desorption isotherm;
BET specific surface measurement (single point/multi-point method)
Langmuir Specific surface;
BJH method pore volume and pore size distribution;
MK-plate method (parallel-plate model) pore volume and pore size distribution;
D-R method micro-hole analysis;
t-plot method (boder) micro-pore analysis;
H-K method (Original) micro pore analysis;
Specifications
|
3H-2000PS1 |
3H-2000PS2 |
3H-2000PS4 |
|
Analysis Stations |
1 |
2 |
4 |
|
Measurement types: |
B.E.T., STSA, adsorption isotherm, desorption isotherm |
|||
Surface area range: |
0.01m2/g to no known upper limit |
|||
Pore size range: |
0.35 to >400nm (3.5 to >4000 Å) |
|||
Minimum pore volume: |
(STP) 0.0001 cc/g |
|||
|
|
|
|
|
Nitrogen |
√ |
√ |
√ |
|
Other non-corrosive gases (Ar, CO2, H2, C4H10, etc.) |
√ |
√ |
√ |
|
Preparation Ports |
2 |
2 |
4 |
|
Methods |
Vacuum |
Vacuum |
Vacuum |
|
Temperature range: |
ambient - 450ºC*, 1ºC intervals |
|||
|
|
|||
Accuracy |
±5ºC |
|||
Accuracy (% of span) |
±0.1 |
±0.1 |
±0.1 |
|
Minimum pressure (mm Hg) resolution |
0.016 |
0.016 |
0.016 |
|
Minimum relative pressure P/Po (N2) resolution |
2 x 10-5 |
2 x 10-5 |
2 x 10-5 |
|
|
|
|
|
|
Dimensions (WxDxH) |
L51cm x W58 cm xH 83cm |
|||
Weight |
32 kg (80 lbs.) |
|||
Electrical |
110-240 V, 50/60 Hz |
The 3H-2000PS Series—designed for today’s laboratory
• Affordably-priced—perfect for any laboratory.
• Space saving—each unit takes up less bench space than an open 3-ring binder.
• Versatile—a wide range of characterization techniques for powdered and porous materials.
• Flexible operation—analysis type independent for each station (BET and/or pore size measurement).
•Prepare two samples by vacuum or flow methods simultaneously with sample analysis—at different temperatures if required.
• Access degasser during analysis to start/stop flow or vacuum degassingwith Analysis Interrupt.
•Eliminate cell calibration with classical helium-void-volume mode.
• Upgradeable—can adapt to meet your expanding or changing laboratory needs.
Unique Features
1. Unique and Innovative mainifold gas control system
2. Use of air control valve to avoid the heat effect of electromagnetic valve
3. Two independent vacuum systems permit simultaneous preparation of two samples while analyzing another.
4. Unique sample pretreatment anti pollution device, effectively prevent powder into the degas and analysis system
5. Long duration dewar provides virtually 70 hours analysis capability
Selection Guide
|
3H-2000PS1 |
3H-2000PS2 |
3H-2000PS4 |
3H-2000PM1 |
3H-2000PM2 |
Degas Stations |
2 |
2 |
4 |
2 |
2 |
Analysis Stations |
1 |
2 |
4 |
1 |
2 |
P0 Test |
√ |
√ |
√ |
√ |
√ |
BET |
√ |
√ |
√ |
√ |
√ |
Total volume |
√ |
√ |
√ |
√ |
√ |
Mesopore(p/p0>10-4) |
√ |
√ |
√ |
√ |
√ |
Micropore(p/p0<10-4) |
--- |
--- |
--- |
√ |
√ |
Isothe |
√ |
√ |
√ |
√ |
√ |
Vacuum Pump |
√ |
√ |
√ |
√ |
√ |
Turbo Vacuum Pump |
--- |
--- |
--- |
√ |
√ |
1000 torr Transducers |
√ |
√ |
√ |
√ |
√ |
10 torr Transducers |
--- |
--- |
--- |
Optional |
Optional |
1 torr Transducers |
Optional |
|
Optional |
√ |
√ |
0.1 torr Transducers |
--- |
--- |
--- |
Optional |
Optional |
Degas Cold Trap |
--- |
--- |
--- |
√ |
√ |
Analysis Cold Trap |
--- |
--- |
--- |
√ |
√ |
3H-2000PS Series Analyzer Test Reports
1 Standard exported package: Internal anticollision protection, external export wooden box packaging.
2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.
3 Responsible for the damage during the shipping process, will change the damaged part for you for free.
DELIVERY TIME:15-20 days after confirming the order, detail delivery date should be decided according to
production season and order quantity.